🏠 Secondary Suites

The definition of “House” has been removed. New rules for ceiling heights and 5/8″ Type X fire separation are now standard for multiplexes.

⚡ Energy Efficiency

SB-12 remains, but 2026 mandates stricter “Tiered” performance. ICF homes inherently meet Tier 3/4 requirements.

💨 Radon Rough-In

Harmonized with the NBC, all new Ontario homes now require a sub-floor depressurization rough-in to mitigate soil gas.

OBC Code Navigator

Get Building Code Answers in Seconds

Ask any Ontario Building Code question in plain English. Get instant answers with Part / Section / Article references you can verify.

Popular questions:
Egress windows Garage separation Deck guards Stair dimensions Ceiling height
2024 Harmonized OBC Part 9 Housing Part 7 Plumbing Instant References

2 free questions • Unlimited access available

📋

Code Navigator Response

📚 OBC References
⚠️Always confirm with your municipality / AHJ / inspector.
🔒

You’ve used your 2 free questions

Unlock unlimited access to the OBC Code Navigator for fast code references anytime.

  • Unlimited questions
  • Answers in under 10 seconds
  • Part / Section / Article references
One-time unlock. Cancel anytime.
Ontario Building Code — Quick Jump (Volumes 1 & 2)
Ontario Building Code • Quick Jump Works in Chrome/Edge/Firefox PDF viewers Links use #page= (PDF page index)

Ontario Building Code sections (Volumes 1 & 2)

Click any section below to open the correct PDF and jump directly to the starting page of that section.

Volume 1

Division A, Division B (Parts 1–12), Division C, Index

Front matter

Division A — Compliance, Objectives and Functional Statements

Division B — Acceptable Solutions

Division C — Administrative Provisions

Back matter

Volume 2

Appendix Notes + Supplementary Standards (SA-1, SB-1 to SB-13)

Appendices

Supplementary Standards

OBC FAQ (2024 Edition) Click a question to reveal the answer

Ontario Building Code FAQ

These are the questions I hear the most from homeowners, cottage owners, and people planning renovations. Click a question to open it. If your project is unusual (or your building department loves red stamps), treat this as guidance and confirm details with your local inspector.

Builder tip: A lot of “code problems” aren’t really code problems — they’re “no permit / no drawings / no inspections” problems. If you get the permit path right early, the rest goes smoother (and cheaper).
1) Do I need a building permit for my project (deck, basement finish, addition, structural change, etc.)? Permits + inspections — the #1 question.

In Ontario, you generally need a permit when you’re creating new space, changing structure, changing plumbing/HVAC systems in a meaningful way, altering fire separations, or doing anything that affects life-safety (stairs, guards, exits). “Cosmetic only” work often doesn’t require a permit, but the moment you move walls, add bedrooms, add bathrooms, modify beams, or build a deck, you’re usually in permit territory. Your local building department is the final referee, and they can require drawings, engineering, and inspections. When in doubt, ask before you build — it’s cheaper than fixing later.

2) What’s the difference between Part 9 and Part 3, and which one applies to my house/project? “Small buildings” vs “larger/complex buildings.”

Part 9 is the “small buildings” section and is what most houses, cottages, and typical residential additions fall under. It’s more prescriptive: it tells you exactly what to do and how to do it for common construction. Part 3 is for larger, more complex buildings (or buildings that exceed Part 9 limits), and it relies more heavily on engineering, fire-resistance ratings, exiting calculations, and detailed design. The trigger is usually building size, occupancy, height, and complexity. If your project is a standard house or duplex-type scenario, you’re often Part 9 — but mixed uses, larger assemblies, or bigger footprints can push you into Part 3.

3) What are the OBC rules for adding a secondary suite (legal basement apartment) in my home? Second units: exits, alarms, separations, ceiling heights, and windows.

A legal secondary suite is more than “a kitchen downstairs.” The OBC rules typically focus on safe exiting, fire separation between units, smoke/CO alarms (often interconnected), minimum ceiling heights, proper heating/ventilation, and emergency escape options (like compliant egress windows where required). Many municipalities also layer on zoning rules, parking requirements, and registration/licensing. The biggest mistakes I see are: missing or incorrect fire separations, no proper egress plan, and trying to “permit it after it’s finished.” Plan it first, submit drawings, and build it to pass inspections — you’ll save money and avoid ugly demolition.

4) What fire separation (drywall rating) and soundproofing is required between a secondary suite and the main dwelling? Fire + sound: two different goals, both important.

Fire separation is about slowing fire and smoke spread, buying time for occupants to get out. Sound control is about quality of life (and fewer tenant wars). The OBC may require specific fire-resistance ratings for walls/ceilings between units, sealed penetrations, and proper duct/fire damper approaches where applicable. Soundproofing is often achieved with resilient channels, insulation, acoustic sealants, and smart framing details — but sound measures don’t automatically equal fire-rated assemblies. The best approach is to design an assembly that meets the fire requirement first, then upgrade for sound with compatible layers and sealing. Your inspector will care about the fire rating; your tenants will care about the sound.

5) What are the minimum ceiling height requirements for basements and secondary suites? Low ceiling = failed inspection = expensive redo.

Ceiling height rules can vary depending on whether it’s a finished basement, a bedroom, a hallway, or a secondary suite, and depending on beams/ducts and other obstructions. Many older homes get caught here: the basement might be “fine for storage,” but not compliant for living space without careful planning. Before you frame anything, measure from the finished floor level you actually intend to build (including subfloor or finished flooring) to the underside of joists and obstructions. If you’re short, you may need options like re-routing ducts, changing beam details, or lowering slabs — and those decisions should happen before permits and finishes.

6) What are the egress window requirements for a basement bedroom? “Can I actually get out if there’s a fire?”

An egress window is about providing a safe emergency escape route. Requirements typically focus on minimum clear opening size (not just glass size), minimum dimensions, and the ability to open without special tools or keys. Window wells also matter: if the well is too small or too deep without steps/ladder provisions, you can still fail. The common mistake is buying a “big-looking” window that doesn’t provide enough clear opening after the sash/frame is considered. If you’re planning a bedroom in a basement, treat egress early as a structural and excavation design question, not a finishing detail.

7) Where do smoke alarms have to be installed, and do they need to be interconnected? Smoke alarms save lives — and inspectors are strict here.

Smoke alarm placement generally depends on sleeping areas, storeys, and the dwelling layout. In many cases you need alarms near bedrooms and on each storey, and they may need to be interconnected so if one triggers, they all sound (especially in newer construction or where required by the OBC and local rules). Secondary suites add another layer because you’re protecting two households, and the code often expects a coordinated alarm strategy. The right move is to follow the manufacturer’s installation requirements, keep them away from dead-air spaces, and confirm the exact locations with your plan reviewer during permitting.

8) Where do carbon monoxide (CO) alarms have to be installed in a house? CO is invisible, odourless, and serious.

CO alarm requirements are tied to fuel-burning appliances (furnaces, water heaters, fireplaces) and attached garages, because those are common CO sources. Placement rules often focus on proximity to sleeping areas and ensuring the alarm can be heard by occupants at night. In many homes, you’ll see CO alarms outside bedrooms and on levels where fuel-burning equipment is present or adjacent spaces exist. Don’t “tuck them away” where they look pretty — put them where they work. Also, CO alarms aren’t a substitute for proper venting and combustion air; they’re a last line of defense when something else goes wrong.

9) Does the 2024 OBC require a radon rough-in, and what exactly must be installed? Radon: plan it before the slab goes in.

Radon measures have become a bigger focus over time, and “rough-in” typically means setting up the building so mitigation can be added easily if testing shows elevated levels. That can involve a sub-slab gas collection layer, sealed slab penetrations, and a vent pipe pathway that can be activated with a fan later. The biggest win is doing it while the foundation is open — it’s inexpensive then and painful afterward. Even with a rough-in, testing is still key because radon levels vary wildly by site. If you want a practical guide, your best approach is: rough-in during construction, then test after occupancy, and activate mitigation if needed.

10) What are the OBC rules for stairs (rise/run), open risers, and maximum openings? Stairs are a tripping hazard… until they’re done right.

Stair requirements usually cover geometry (rise and run), consistency (no surprise step sizes), headroom, landings, and limitations on openings where a child could slip through. Open risers are sometimes allowed, but there are constraints on the size of openings and where they can be used. Inspectors pay attention to “uniformity” because even small variations can cause falls, especially on poorly lit stairs. If you’re renovating, be careful: changing flooring thickness or adding stair nosings can throw off rise/run compliance. The safest path is to design the stair as a system (including finished flooring), not as a framing afterthought.

11) What are the minimum guardrail heights and handrail requirements for stairs, landings, decks, and balconies? Guards: you only notice them when they’re missing.

Guard and handrail rules are about preventing falls and providing support — especially for kids and older adults. Requirements commonly depend on the height of the drop, the location (stairs vs landings vs decks), and sometimes the building type. You’ll often see rules around minimum heights, handrail graspability, continuity, and maximum openings between balusters. A beautiful guard that fails spacing is still a fail. The easiest way to avoid headaches is to choose a guard system that is designed for code compliance and install it exactly per manufacturer details. If you want to jump straight to the stairs/guards area in Volume 1, use the link in your page that targets the relevant Part 9 pages.

12) When do Ontario accessibility / barrier-free requirements apply to residential buildings? Not every home is “accessible,” but some rules can still apply.

Accessibility requirements (often called “barrier-free” in the code context) are more commonly triggered in public buildings, larger multi-unit residential, and certain project types where the public has access. Typical single-family homes don’t usually face the same barrier-free requirements as commercial buildings, but specific situations can bring accessibility into the conversation—especially when you’re dealing with multi-unit buildings, shared entrances, or certain regulated occupancies. Even when not mandatory, designing with accessibility in mind (wider doors, fewer steps, clear paths, better lighting) is a smart investment for aging in place and resale value. For the official provincial guidance, your page links to Ontario’s accessibility OBC information.

13) What are the OBC rules for deck construction and when is a permit required? Decks look simple… right up until they fail.

Deck permits are usually tied to height, attachment to the house, size, and structural risk. Even a “small” deck can require a permit if it’s elevated or attached. Common code focus areas are: frost protection for footings, beam and joist sizing, ledger attachment details, lateral bracing, and guard requirements. The failure points I see most: shallow or undersized footings, poor ledger attachment, and guards that don’t meet height/spacing. Use a tested deck guide (your page already links to a deck code PDF), submit drawings when required, and don’t wing it—decks are one of the most common inspection failures.

14) What are the minimum requirements for foundation/footing frost protection (depth, insulation options, etc.)? Frost is undefeated. Don’t argue with it.

Frost protection is about preventing heaving, shifting, and cracking caused by freezing soils. Traditional solutions rely on footings below frost depth, but some designs can use engineered insulation strategies for frost-protected shallow foundations in appropriate situations. Requirements depend on climate region, soil conditions, groundwater, and building type. The “cheap” route (shallow footings without proper design) becomes extremely expensive when doors stick, slabs crack, or decks start leaning. The right move is to design foundation depth and insulation based on your site, not your neighbour’s guess. Your building department may also have local expectations because frost behaviour varies by area.

15) When finishing a basement, what are the code rules for exits, fire blocking, insulation, and vapor barrier? Basement finishing is where “hidden” mistakes get expensive.

A basement finish isn’t just drywall and flooring. Code concerns often include safe exiting (especially if you add bedrooms), smoke/CO alarm coverage, proper fire blocking in concealed spaces, and correct insulation/vapour control so you don’t build a mold farm behind your walls. You also need to think about combustion air and venting if mechanical systems are in the basement, plus clearances to electrical panels and equipment. The most common fail is trapping moisture: wrong vapour barrier placement, gaps around windows, or insulating in a way that encourages condensation. Plan the assembly, confirm the details with your inspector, and don’t cover anything until you pass the rough inspections.

16) What are the OBC requirements for ventilation (HRV/ERV), bathroom fans, and kitchen exhaust in new homes? Modern homes need deliberate fresh air, not wishful thinking.

As homes get tighter for energy efficiency, ventilation becomes a designed system, not a crack under the door. The OBC typically expects controlled ventilation that can provide fresh air and remove moisture and pollutants. That often means an HRV/ERV strategy, properly ducted bathroom exhaust, and kitchen exhaust that actually moves air outside. Poor ventilation shows up as condensation, window sweating, stale air, and comfort complaints. The key is balancing: you want enough airflow to keep indoor air healthy without creating drafts, backdrafting combustion appliances, or pulling radon/soil gases. Get the ventilation plan right early, and your home feels better for decades.

17) What are the rules for plumbing changes (adding a bathroom, moving drains/vents, sump pits, backwater valves)? Plumbing is code-heavy because failures are messy and unhealthy.

Plumbing rules cover drainage, venting, trap protection, cleanouts, pipe sizing, and backflow protection. Adding a bathroom or moving fixtures can trigger permit requirements and inspections because incorrect venting leads to siphoned traps and sewer gas, and incorrect drainage leads to clogs and backups. Sumps and backwater valves are particularly important in many Ontario areas due to groundwater and storm events. The big mistake is treating plumbing like “it’ll probably flow downhill.” It will — until it doesn’t. If you’re reworking plumbing, pull the permit if required, follow the correct venting/drain rules, and get it inspected before you bury it in concrete or walls.

18) What are the OBC requirements for septic / sewage systems (Part 8) and what approvals are needed? Septic is engineering + soil + approvals, not guesswork.

Septic systems are governed by OBC Part 8 and require proper design based on bedroom count, expected flows, soil conditions, and site constraints. In many cases you’ll need a qualified designer, a soil evaluation, and approvals from the authority having jurisdiction (which can vary by municipality). The system type (conventional, raised bed, tertiary, etc.) depends heavily on percolation and available area. The most common mistakes are undersizing, trying to squeeze a system onto a small lot without planning, and ignoring setbacks to wells, water bodies, and property lines. If you’re buying a lot, confirm septic feasibility early — it can make or break the entire project budget.

19) Can I use an Alternative Solution if I want to do something different than the prescriptive code, and who approves it? Yes — but you need proof, not opinions.

The OBC allows Alternative Solutions when you want to deviate from prescriptive “Acceptable Solutions” but still meet the code’s objectives. In plain English: you can do it differently if you can prove it performs equivalently for safety, health, accessibility, and performance objectives. Approval typically involves documentation, engineering, testing data, manufacturer evaluations, or other professional justification — and the building official (or a designated authority) reviews it. Alternative Solutions are common with innovative products, unique assemblies, or unusual designs. The success factor is documentation: if you show compliance clearly, it can be smooth; if it’s hand-wavy, it becomes a long, expensive conversation.

20) What happens if someone builds without a permit or doesn’t call for inspections—what are the penalties and fixes? Short answer: it gets expensive fast.

Building without permits or skipping inspections can lead to stop-work orders, fines, legal orders to uncover work, and forced corrections. It also becomes a major issue when you sell the home or try to insure it, because unpermitted work is a red flag for lenders, buyers, and insurers. The worst scenario is having to demolish finished areas to prove what’s inside the walls — structure, insulation, fire separation, wiring, plumbing — all of it. If you’ve already started without a permit, the best move is to talk to the building department immediately and get on a path to compliance. “Hiding it” rarely works long-term, and it usually costs more than doing it properly in the first place.