Lintel and Header Span Tables Ontario (2027)
Ontario Building Code 2024 lintel span tables for 2x8, 2x10 and 2x12 headers over windows and doors, in feet and inches, by snow load and storeys carried.

What Size Header Goes Over That Opening? The Ontario Lintel Tables, In Plain Feet And Inches
Every window and door is a hole in a wall that was holding something up. The lintel, which most framers just call the header, carries that load across the gap. The Ontario Building Code says how far each size can go. Here are the spruce-pine-fir tables, converted to feet and inches.
Let Me Lower Your Expectations First
People are always surprised how short these numbers are. A patio door eight feet wide in a two-storey wall is already past what doubled 2×12 lumber is allowed to do in most of Ontario.
That is not the Code being fussy. A header carries everything above the opening down to two small bearing points, and it does it for the life of the house, through every snow load the roof ever sees. A header that is a little too light does not fail on day one. It sags over ten years, and the first you hear of it is a door that will not latch.
I build houses. I am not an engineer. These tables are copied from the Code and checked, but your permit drawings and your building department decide what goes in your wall.
First, Know Your Snow Load
Lintel spans in an exterior wall depend on the specified snow load for where you live, which the Code works out from local climate data. It is not the same number across Ontario. The snowbelt off Georgian Bay and Lake Huron carries a lot more than Windsor does.
Your building department will tell you the figure they use. You can also look at snow loads in Ontario and our snow load calculator. If you land between two tables, use the heavier one.
Exterior Walls: Specified Snow Load 2.0 kPa
| 2-ply lintel | Roof and ceiling only | Roof, ceiling and 1 storey | Roof, ceiling and 2 storeys |
|---|---|---|---|
| 2 – 2×4 2 – 38 x 89 mm | 3′-3″ 1.01 m | 2′-11″ 0.89 m | 2′-8″ 0.83 m |
| 2 – 2×6 2 – 38 x 140 mm | 4′-10″ 1.48 m | 4′-2″ 1.27 m | 3′-10″ 1.19 m |
| 2 – 2×8 2 – 38 x 184 mm | 5′-10″ 1.80 m | 5′-1″ 1.55 m | 4′-8″ 1.44 m |
| 2 – 2×10 2 – 38 x 235 mm | 7′-2″ 2.20 m | 6′-2″ 1.89 m | 5′-7″ 1.72 m |
| 2 – 2×12 2 – 38 x 286 mm | 8′-4″ 2.56 m | 7′-0″ 2.15 m | 6′-5″ 1.96 m |
Exterior Walls: Specified Snow Load 2.5 kPa
| 2-ply lintel | Roof and ceiling only | Roof, ceiling and 1 storey | Roof, ceiling and 2 storeys |
|---|---|---|---|
| 2 – 2×4 2 – 38 x 89 mm | 3′-0″ 0.93 m | 2′-9″ 0.84 m | 2′-7″ 0.79 m |
| 2 – 2×6 2 – 38 x 140 mm | 4′-5″ 1.35 m | 3′-10″ 1.19 m | 3′-8″ 1.13 m |
| 2 – 2×8 2 – 38 x 184 mm | 5′-4″ 1.64 m | 4′-8″ 1.44 m | 4′-4″ 1.33 m |
| 2 – 2×10 2 – 38 x 235 mm | 6′-7″ 2.01 m | 5′-8″ 1.73 m | 5′-2″ 1.60 m |
| 2 – 2×12 2 – 38 x 286 mm | 7′-7″ 2.33 m | 6′-5″ 1.96 m | 5′-11″ 1.82 m |
Exterior Walls: Specified Snow Load 3.0 kPa
| 2-ply lintel | Roof and ceiling only | Roof, ceiling and 1 storey | Roof, ceiling and 2 storeys |
|---|---|---|---|
| 2 – 2×4 2 – 38 x 89 mm | 2′-10″ 0.87 m | 2′-7″ 0.79 m | 2′-5″ 0.76 m |
| 2 – 2×6 2 – 38 x 140 mm | 4′-1″ 1.25 m | 3′-8″ 1.13 m | 3′-5″ 1.06 m |
| 2 – 2×8 2 – 38 x 184 mm | 4′-11″ 1.52 m | 4′-4″ 1.33 m | 4′-1″ 1.25 m |
| 2 – 2×10 2 – 38 x 235 mm | 6′-0″ 1.84 m | 5′-2″ 1.59 m | 4′-11″ 1.50 m |
| 2 – 2×12 2 – 38 x 286 mm | 6′-10″ 2.09 m | 5′-11″ 1.81 m | 5′-7″ 1.71 m |
Source: 2024 Ontario Building Code, Span Table 9.23.12.3.-C, spruce-pine-fir No. 1 or No. 2, non-structural sheathing. “Roof and ceiling only” is the column for a tributary width of up to 4.9 m. Lintels are two pieces of 38 mm lumber on edge. The Code figure is the metric one; feet and inches are rounded down to the inch.
Interior Bearing Walls
An interior wall does not carry snow directly, so one table covers every part of the province.
| 2-ply lintel | Limited attic storage and ceiling | Roof, ceiling and 1 storey | Roof, ceiling and 2 storeys |
|---|---|---|---|
| 2 – 2×4 2 – 38 x 89 mm | 4′-2″ 1.27 m | 2′-5″ 0.74 m | 2′-1″ 0.64 m |
| 2 – 2×6 2 – 38 x 140 mm | 6′-3″ 1.93 m | 3′-4″ 1.02 m | 2′-10″ 0.88 m |
| 2 – 2×8 2 – 38 x 184 mm | 7′-8″ 2.35 m | 3′-11″ 1.20 m | 3′-5″ 1.05 m |
| 2 – 2×10 2 – 38 x 235 mm | 9′-5″ 2.88 m | 4′-9″ 1.45 m | 4′-2″ 1.27 m |
| 2 – 2×12 2 – 38 x 286 mm | 10′-11″ 3.34 m | 5′-5″ 1.66 m | 4′-9″ 1.45 m |
Source: 2024 Ontario Building Code, Span Table 9.23.12.3.-C, interior walls column.
If you are cutting a new opening in a wall like this, or taking the wall out altogether, read what it costs to remove a load-bearing wall first. A new opening in an old bearing wall needs a permit.
The Fine Print That Changes The Answer
The notes under the Code table matter as much as the numbers. In plain words:
- Structural sheathing adds 15%. Where structural panel sheathing, at least 9.5 mm thick, is fastened to the outside face of the lintel the way the Code describes, the spans may be increased by 15%.
- Short framing above adds 5%. The table assumes joists or rafters spanning up to 4.9 m and roof trusses up to 9.8 m. If yours are no more than 4.3 m and 8.6 m, the spans may be increased by 5%.
- Clear-span floors take away. If the floor joists run the full width of the building with no support in between, reduce the span by 15% under one storey, 20% under two and 25% under three.
- Bearing. Each end needs at least 38 mm (1 1/2″) of bearing for spans up to 3 m, and 76 mm (3″) beyond that. In practice that means one jack stud each side for the short ones and two for the long ones.
- A solid piece is allowed. One piece of 89 mm thick lumber may be used in place of two pieces of 38 mm on edge.
Rule of thumb
These tables cover an even load from a normal roof and floor. A header with a beam, a girder truss or a post landing on it is carrying a point load, and no table on this page applies. That one gets sized by an engineer or the lumber supplier.
Where Homeowners Go Wrong!
- They widen a window and keep the old header. The old header was sized for the old opening. A wider window is a longer span and a bigger load.
- They measure the window, not the opening. The span is the clear distance between the jack studs, which is wider than the window unit.
- They forget what is above. The same opening needs a bigger header on the main floor of a two-storey than it does upstairs.
- They cut the jacks short. A good header on one skinny stud crushes the stud instead. The bearing is part of the header.
- They assume the truss guy looked after it. A girder truss lands a big load on one spot. Somebody has to make sure there is not a window under it.
Planning new windows or doors? Our windows and doors guide covers the rest of the job, and the framing inspection checklist shows what the inspector checks around openings.
Questions I Get Asked
What size header do I need for a 6-foot opening?
In an exterior wall carrying only a roof at 2.0 kPa, a doubled 2×10 (good for 7′-2″) covers it. With one storey above, a doubled 2×10 is good for 6′-2″, so it just makes it at 2.0 kPa and falls short at higher snow loads, where you go to a doubled 2×12 or engineered lumber.
Can I use three plies instead of two?
The table on this page is the Code’s table for two-ply lintels. Wider walls are often framed with three plies, but do not guess the extra span. Have it confirmed on your drawings.
What about LVL or steel?
Both go farther than sawn lumber and both are sized from the manufacturer’s tables or by an engineer, not from this page. See LVL vs steel beam.
Is a lintel the same as a header?
On a wood-framed house, yes. The Code says lintel, the framer says header, and they mean the same piece of wood.
Sources And Further Reading
- 2024 Ontario Building Code Compendium, Part 9: Span Tables 9.23.12.3.-A to -D and their notes.
- City of North Bay span table handout, which includes the spruce lintel table.
- Canadian Wood Council.
Opening Up A Wall?
Price the job before the saw comes out, and find out whether it needs a stamp.
Information only. Not engineering advice. Spans are for spruce-pine-fir No. 1 or No. 2 two-ply lintels under the 2024 Ontario Building Code; the metric values govern. Confirm against your permit drawings and your building department.